SMT paste-volume SPC sample report
Entirely synthetic teaching data — not records from a real factory, customer or instrument.
One fixed pad characteristic, one reading per board, collected on a single fictional line. Inspect the completed report, then download the same data to reproduce the analysis.
Scenario and interpretation boundaries
Volume is percent of nominal volume (% nominal), not mm³. The 80% and 120% limits are invented teaching specifications, not IPC standards, instrument recommendations or customer requirements. Do not pool different pads, nominal volumes or lines without a justified plan.
Free to view, download and print without registration. This page contains only public synthetic data; custom measurements are processed locally in the workbench. This sample does not promise SPI Word reports or a paid entitlement.
Customer-facing English summary — teaching example
This synthetic sample contains 40 measurements of the same pad characteristic on 40 distinct boards. 1 of 40 measurements (2.5%) are outside the invented 80–120% nominal-volume limits. SYN-021 is the out-of-specification board. The preliminary I-MR analysis flags 3 point-beyond-limit signals, including moving ranges involving adjacent boards. Investigate the signals and measurement/sampling assumptions before predicting process performance. The displayed capability indices assume a normal model and are descriptive only; this report does not approve a shipment or establish a root cause.
SPC analysis report
Measurements and specification limits retain parsed numeric precision. Other displayed values are rounded to seven significant digits; signals and specification counts use unrounded numbers. This page downloads raw synthetic data. Reproduce the analysis using the steps below, then export full-precision calculated results from the workbench.
40 measurements in 40 rows; 1 per row. Unit: % nominal. Selected source columns: 6: paste_volume_pct. Header: yes; decimal mark: point. No sorting, missing-value deletion or exclusions.
Method passport — this local snapshot
| Snapshot schema / dataset revision | 1 / 3 |
|---|---|
| Method ID | imr-mr2-nist-v1 |
| Within method / constants | mr2-d2; d2 = 1.128; D3 = 0; D4 = 3.267; mrSpan = 2 |
| Overall method | sample-sd-n-minus-1; No c4 correction for overall sample SD |
| Baseline / signal rules | Phase I: all retained measurement records; Points outside the displayed control limits only |
| Confirmed measurement plan | Collection order and one characteristic in a consistent unit confirmed; individual observations. Unit: % nominal. |
| Source records | 41 CSV records; 1 header record; 40 measurement records; 0 measurement records omitted. Unselected columns: 1, 2, 3, 4, 5, 7, 8. |
| Model assumption | Normal model explicitly assumed, not tested. |
This page is a fixed teaching snapshot generated when the site is built, not an editable project or an audit certificate. CSV record numbers count parsed records rather than physical text lines. Open the workbench to analyse your own data.
Method and data summary
Within σ: MR̄ / 1.128; moving range span = 2. Overall s: √[Σ(x−mean)²/(N−1)], no c₄ correction.
| Mean | 100.75 |
|---|---|
| Within σ estimate | 3.568831 |
| Overall sample s | 4.743416 |
| LSL (requirement) | 80 |
| USL (requirement) | 120 |
Stability screen
3 point-beyond-limit signals; investigate special causes.
- Only the point-beyond-3σ rule is checked. No signals does not establish stability; review runs, dependence, sampling and measurement-system suitability.
- Control limits are estimated from all imported rows (Phase I), not validated future monitoring limits.
- Fewer than 100 measurements: capability estimates may have substantial uncertainty.
- Special-cause signals found. Capability indices are descriptive only; investigate before predicting performance.
- Normal model assumed, not proven. No predicted defect rate, confidence interval or pass/fail verdict is provided.
Individuals chart
On a narrow screen, scroll the chart horizontally to read its labels.
Moving range chart
On a narrow screen, scroll the chart horizontally to read its labels.
Observed specification results
1 of 40 measurements outside the supplied limits (2.5%). Values exactly on a limit count as within. This is an observed sample count, not a prediction.
Descriptive capability comparison
| Index | Within estimate | Overall sample SD |
|---|---|---|
| Cp / Pp | 1.868025 | 1.405457 |
| CPL / PPL | 1.938076 | 1.458161 |
| CPU / PPU | 1.797975 | 1.352752 |
| Cpk / Ppk | 1.797975 | 1.352752 |
No automatic acceptance decision. Cp/Pp = (USL−LSL)/(6σ); CPU/PPU = (USL−mean)/(3σ); CPL/PPL = (mean−LSL)/(3σ). Cpk/Ppk use the smaller available side. Negative values are retained when the mean lies outside a requirement.
Signals
I data row 21 / source record 22: 128; MR data row 21 / source record 22: 27; MR data row 22 / source record 23: 27
DIYMathLab SPC Workbench — preliminary Phase I analysis. Consult the method notes on this page before using results.
Audit table: all 40 analysed rows
| Data row / source record | Measurements | Mean / individual | Range / moving range |
|---|---|---|---|
| 1 / 2 | 98 | 98 | Not defined |
| 2 / 3 | 101 | 101 | 3 |
| 3 / 4 | 99 | 99 | 2 |
| 4 / 5 | 102 | 102 | 3 |
| 5 / 6 | 100 | 100 | 2 |
| 6 / 7 | 97 | 97 | 3 |
| 7 / 8 | 103 | 103 | 6 |
| 8 / 9 | 100 | 100 | 3 |
| 9 / 10 | 99 | 99 | 1 |
| 10 / 11 | 101 | 101 | 2 |
| 11 / 12 | 98 | 98 | 3 |
| 12 / 13 | 101 | 101 | 3 |
| 13 / 14 | 99 | 99 | 2 |
| 14 / 15 | 102 | 102 | 3 |
| 15 / 16 | 100 | 100 | 2 |
| 16 / 17 | 97 | 97 | 3 |
| 17 / 18 | 103 | 103 | 6 |
| 18 / 19 | 100 | 100 | 3 |
| 19 / 20 | 99 | 99 | 1 |
| 20 / 21 | 101 | 101 | 2 |
| 21 / 22 | 128 | 128 | 27 |
| 22 / 23 | 101 | 101 | 27 |
| 23 / 24 | 99 | 99 | 2 |
| 24 / 25 | 102 | 102 | 3 |
| 25 / 26 | 100 | 100 | 2 |
| 26 / 27 | 97 | 97 | 3 |
| 27 / 28 | 103 | 103 | 6 |
| 28 / 29 | 100 | 100 | 3 |
| 29 / 30 | 99 | 99 | 1 |
| 30 / 31 | 101 | 101 | 2 |
| 31 / 32 | 98 | 98 | 3 |
| 32 / 33 | 101 | 101 | 3 |
| 33 / 34 | 99 | 99 | 2 |
| 34 / 35 | 102 | 102 | 3 |
| 35 / 36 | 100 | 100 | 2 |
| 36 / 37 | 97 | 97 | 3 |
| 37 / 38 | 103 | 103 | 6 |
| 38 / 39 | 100 | 100 | 3 |
| 39 / 40 | 99 | 99 | 1 |
| 40 / 41 | 101 | 101 | 2 |
Trace chart signals to synthetic boards
An MR row represents the difference between adjacent boards in volume percentage points. It does not mean both boards are outside specifications. This trace follows the point-beyond-limit rule only; it does not identify a proven equipment or process cause.
| Chart | Data row / CSV record | Board or adjacent boards | Time (UTC) | Plotted value |
|---|---|---|---|---|
| I | 21 / 22 | SYN-021 | 2026-01-15T08:20:00Z | 128 |
| MR | 21 / 22 | SYN-020 → SYN-021 | 2026-01-15T08:20:00Z | 27 |
| MR | 22 / 23 | SYN-021 → SYN-022 | 2026-01-15T08:21:00Z | 27 |
Method and limitations
This small sample uses individuals I-MR with a moving-range span of 2, within sigma = mean moving range / 1.128, and overall sample SD with N−1. Limits use all 40 readings and only point-beyond-limit screening. This does not establish stability, independence or normality. Capability with these signals is a method demonstration, not a forecast. No automatic deletion, causal diagnosis, predicted defect rate or shipment acceptance is provided.
Method references: NIST — Shewhart control charts; NIST — process capability.
Reproduce this report in the workbench
- Download the CSV, open SPC Workbench, then choose it with “Open a local CSV or TSV file”. The start link does not preload or transfer data.
- Choose comma separator, decimal point and first-row header, then inspect. Select only column 6, paste_volume_pct. Other columns identify the scenario or carry specifications, not extra measurements.
- Choose individuals and enter % nominal as the unit. Confirm collection order and consistent characteristic/unit. This example already contains only SYN-L1, SYN-0603 and SYN-U1-P1; the workbench does not automatically filter metadata.
- To reproduce the example, manually enter LSL=80 and USL=120, then explicitly select the normal-model assumption to show descriptive capability. Specification columns do not automatically set limits. Real analyses require actual engineering requirements.
- Analyse and check 40 measurements, 1 measurement outside specifications and synthetic board SYN-021. Capability is descriptive under the stated assumptions; investigate signals rather than treating them as shipment approval or future conformity. Print / Save PDF opens the browser print dialog.
Columns in the download
board_id- Unique synthetic board identifier
measured_at- UTC collection time in ISO 8601; already in collection order
line_id- Fictional line SYN-L1
pad_class- Fictional pad class SYN-0603
pad_id- The same repeated pad characteristic SYN-U1-P1 on each board
paste_volume_pct- Only analysed column: percent of nominal volume
lsl_pct / usl_pct- Invented 80 / 120 limits; enter manually, do not select as measurements